Primo 10.0-1 208-240 Inverter
$3,474.90
Out of stock
Description
FRONIUS PRIMO
POWER GENERATION THAT LASTS.
With power categories ranging from 3.8 kW to 15.0 kW, the transformerless Fronius Primo is the ideal compact single-phase inverter for residential applications. The sleek design is equipped with the SnapINverter hinge mounting system which allows for lightweight, secure and convenient installation. The Fronius Primo has several integrated features that set it apart from competitors including dual powerpoint trackers, high system voltage, a wide input voltage range, Wi-Fi* and SunSpec Modbus interface, and Fronius’ online and mobile monitoring platform Fronius Solar.web. The Fronius Primo also works seamlessly with the Fronius Rapid Shutdown Box for a reliable NEC 2014 690.12 and NEC 2017 690.12(B)(1) solution.
INPUT DATA
Number of MPPT | 2,0 |
---|---|
Recommended PV Power (kWp) | 8.0 – 12.0 kW |
Max. usable input current | 33,0 / 18,0 A |
Max. usable input current total (MPPT1 + MPPT2)
|
51,0 A |
Max. array short circuit current (1.5 * Imax)
|
49,5 / 27 A |
Nominal input voltage
|
415 V |
Operating voltage range
|
80 – 600 V |
MPP Voltage Range
|
220 – 480 V |
Max. input voltage
|
1000 V |
Integrated DC string fuse holders | 4- and 4+ for MPPT 1 / no fusing required on MPPT 2 |
OUTPUT DATA
Max. output power 240 V | 9995 VA |
---|---|
Max. output power 208 V | 9995 VA |
Output configuration
|
1~ NPE 208 / 240 V |
Frequency range | 45 – 66 Hz |
Nominal operating frequency | 60,0 Hz |
Total harmonic distortion | < 2,5 % |
Power factor range
|
0 – 1 ind./cap. |
Max. continuous output current 240 V | 41,6 A |
Max. continuous output current 208 V | 48,1 A |
OCPD/AC breaker size 240 V | 60 A |
OCPD/AC breaker size 208 V | 70 A |
Max. efficiency | 97,9 % |
CEC efficiency 240 V | 96,5 % |
GENERAL DATA
Dimension (width) | 1,68 ft |
---|---|
Dimension (height) | 2,38 ft |
Dimension (depth) | 8,9 in |
Weight | 82,47 lbs |
Protection class | NEMA 4X |
Night time consumption | < 1 W |
Inverter topology | Transformerless |
Cooling | Variable speed fan |
Elevation | 4000 m (13120 ft) with a max. input voltage of 1000 V |
Certificates and compliance with standards | UL 1741-2010 Second Edition (incl. UL1741 Supplement SA 2016-09 for California Rule 21 and Hawaiian Electric Code Rule 14H), UL1998 (for functions: AFCI, RCMU and isolation monitoring), IEEE 1547-2003, IEEE 1547.1-2003, ANSI/IEEE C62.41, FCC Part 15 A & B, NEC 2017 Article 690, C22. 2 No. 107.1-16, UL1699B Issue 2 -2013, CSA TIL M-07 Issue 1 -2013 |
DC connection terminals | 4x DC+1, 2x DC+2 and 6x DC- screw terminals for copper (solid / stranded / fine stranded) or aluminum (solid / stranded) |
AC connection terminals | Screw terminals 12 – 6 AWG |
Revenue Grade Metering | Optional (ANSI C12.1 accuracy) |
Additional information
Weight | 82.5 lbs |
---|---|
Dimensions | 28.5 × 20.1 × 8.9 in |